PIV Tool PIVViewBatch

For processing lots of data the PIVViewBatch software was programmed:

• Distributes the PIVView kernel to all available user specified cores
• Collects the data and build averages
• Processing power scales linearly with number of cores

• Platform independant

• Distributes the data over the network

PIV Software PIVTecILA

We are combining the well known PIVView core with a new user interface and add some tools for effective number crunching.

• Proven accurate and very fast PIV code
• Very easy to use interface
• Platform independant Windows, Linux and Mac OS supported
• One click Evaluation with default parameter
2D-LDA Beam Combination Unit September 2009

Combine your existing fp50 probe with another one and build a flexible 2D-LDA system. Both systems can be still used separately!

• Flexible and modular
• Very easy to use
• Different laser sources usable
• Both LDA systems can be still used separately
fp40 with Stand alone Controller September 2009

LDV doesn't have to be expensive! This robust and easy to use LDV system was especially designed for stand alone industrial applications. Very precise and modern alternative for hotwire anemometer.

• Small, compact and low-cost
• High accuracy
• High long term stability
• Usable for calibration or educational purposes
Remote Focus Tilt Mounts August 2009

Tilt mount with Remote focus and aperture control for Canon EOS lenses

• Camera angle 360°
• Tilt angle +/- 20°
• Native pco camera support
• Other cameras easily adaptable
• RS232 control
• Comfortable control software
New PIVSync available May 2009

New ILA Network based PIVSyncronizer with fantastic features

• 5ns resolution – 200 MHz internal clock rate

• TCP/IP interface
• completely configurable trigger logic
Some LDA News March 2009

New fp40 Laser Diode based system with 30mW output power. Dimension only (L) 130mm (W) 45mm (H) 45mm!

• Laser power 30mW@785nm
• Fixed optical path length compensated beam splitters
• Focal length: 160, 200mm
• Beam distance: 35mm
• accuracy better than 0,5% for f=200mm
• Velocity range  for f=200mm: 0,005-30m/s
Newsletter July 2005

Welcome to the July 2005 edition of our Newsletter for highlights on some of ILA´s most recent developments. Have a look at:

- Application examples for ILA's most recent High-Speed PIV systems

- A lLight sheet generator for dual-plane PIV

- The new fp80-fiber LDV probe

- A new product for industry: the PRIOS profilemeter

- ILA's range of measurement services

- The appointment of a new partner in Switzerland, Optolution SA

Download the
Newsletter
in pdf file format
Newsletter October 2004

Welcome to the seventh edition of our Newsletter for highlights on some of ILA´s most recent developments. Have a look at:

- ILA's new Standard range of PIV systems

- CARLA, a custom-designed laser illumination system for CIRA's icing wind tunnel facility

- New remote-control options for PIV systems

- A new range of modular ILA traversing systems

- The MiniPIV synchroniser

- Integrated support in VidPIV 4.6XP for the new pco.xx00 range of PCO cameras

Download the
Newsletter
in pdf file format
New PIV/LIF Software Brochure

October 27, 2004

We have just completed a comprehensive update of the VidPIV software brochure, including detailed coverage of the latest algorithms and features of version 4.6XP. Have a look in the download section of our site!

PIV Syncronizer Software

September 06, 2004

A standalone software interface for the ILA syncronizer is now available to our existing customers. This interface performs the same functions as the command menus controlled from the front panel of the syncronizer. The commands are sent via one of the USB ports. This interface is fully compatible with all the existing versions of the USB-equipped syncronizer. Dowload it from our customer support area...

High Performance Cost-Effective PIV Range

September 02, 2004

ILA have recently launched a new range of PIV systems with particularly attractive pricing. The systems integrate high performance, high quality core components, but rely on more standardisation and a more modular approach to achieve lower production costs. The range includes the following configurations: 2D, 2D Notebook, 3D stereo, High-Speed (up to 5kHz) and Micro-PIV. The systems share the same main components, so we can offer attractive upgrade conditions. A standard upgrade kit is available from 2D tp 3D stereo.

Prices start at €36,500 for a 2x15mJ 2D system (€39,500 for 2 x 30mJ) while 3D stereo system prices start at prices below €50,000.

Download pdf datasheet
10th Anniversary Special Low-Cost PIV Offer

July 09, 2004

To celebrate their 10th Anniversary, ILA introduce a special PIV offer: a complete PIV system, including all image capture, illumination and processing hardware, for less than €40,000. Ofcourse, this is for a fully functional, high performance system, based on the PCO Pixelfly QE cross-correlation camera. No corners cut on either the hardware or the software.

Download our datasheets, or talk to an ILA representative for more information!

Download pdf datasheet (2 x 15mJ system)

Download pdf datasheet (2 x 30mJ system)

Industrial Flowmeter Calibration

July 09, 2004

ILA presents their new range of online flowmeter calibrations systems. Designed for highly accurate calibration of industrial flowmeters, these systems can quickly generate very significant savings!

Download pdf datasheet (157KB)
Newsletter March 2004


Welcome to the sixth edition of our Newsletter for highlights on some of ILA´s most recent developments. Have a look at:

Noise Reduction Node
Correction of Stereo Mapping
Additional Stereo Nodes
New POD Analysis Node

Complete package for a very attractive price

Completely remote controlled motorised Scheimpflug Adapter


Download the
pdf-file
Newsletter pdf

Advanced Software Tools for PIV



MicroPIV System

New PIV Hardware

Newsletter September 2002


Welcome to the fifth edition of our Newsletter for highlights on some of ILA‘s most recent developments. Have a look at:

New Adaptive Cross Correlation
Node using Subpixel Interpolation with reduced Peak Locking

Using the Evolution-30 laser and Phantom
v5.0 camera ILA

New Flash-upgradeable Syncronizer

Endoscopic Light Sheet Optic with a diameter of only 8 mm and a complete Endoscopic PIV System

PCO did a very good job again, so we are proud to announce the new SensiCam QE


Download the
pdf-file
Newsletter pdf

Advanced Software Tools for PIV

High Speed PIV


New PIV Hardware